<?xml version="1.0" encoding="UTF-8"?>
<RE_Register xmlns:gmd="http://www.isotc211.org/2005/gmd"
             xmlns:gco="http://www.isotc211.org/2005/gco"
             xmlns:xlink="http://www.w3.org/1999/xlink"
             xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
             xmlns="http://www.isotc211.org/2005/grg"
             xsi:schemaLocation="http://www.isotc211.org/2005/grg http://standards.iso.org/iso/19135/-2/reg/1.0/registration.xsd">
   <name>
      <gco:CharacterString>Art des hydraulischen Tests</gco:CharacterString>
   </name>
   <contentSummary gco:nilReason="missing"/>
   <uniformResourceIdentifier>
      <gmd:CI_OnlineResource>
         <gmd:linkage>
            <gmd:URL>https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9</gmd:URL>
         </gmd:linkage>
      </gmd:CI_OnlineResource>
   </uniformResourceIdentifier>
   <operatingLanguage>
      <RE_Locale>
         <name>
            <gco:CharacterString>german</gco:CharacterString>
         </name>
         <language>
            <gmd:LanguageCode codeList="http://www.loc.gov/standards/iso639-2" codeListValue="ger">ger</gmd:LanguageCode>
         </language>
         <country gco:nilReason="missing"/>
         <characterEncoding>
            <gmd:MD_CharacterSetCode codeList="http://www.isotc211.org/2005/resources/Codelist/gmxCodelists.xml"
                                     codeListValue="utf8"/>
         </characterEncoding>
         <citation gco:nilReason="missing"/>
      </RE_Locale>
   </operatingLanguage>
   <alternativeLanguages gco:nilReason="inapplicable"/>
   <owner gco:nilReason="inapplicable"/>
   <submitter gco:nilReason="inapplicable"/>
   <containedItemClass>
      <RE_ItemClass>
         <name>
            <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
         </name>
         <technicalStandard gco:nilReason="inapplicable"/>
         <alternativeNames gco:nilReason="inapplicable"/>
         <describedItem gco:nilReason="inapplicable"/>
      </RE_ItemClass>
   </containedItemClass>
   <manager gco:nilReason="missing"/>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PV">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Pumpversuch</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Kontrolliertes Feldexperiment, bei dem Grundwasser aus einem oder mehreren Brunnen entnommen wird. Aus den beobachteten Änderungen der Wasserstände, der dokumentierten Fördermenge und Grundwasserbeschaffenheit können geohydraulische, hydrochemische und betriebliche Informationen gewonnen werden.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Temporary abstraction of water from one or more wells to determine geohydraulic parameters and abstraction-related changes in groundwater properties.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PV"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVku">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Kurzzeitpumpversuch</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Pumpversuch mit einer Dauer von weniger als 24 Stunden.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>pumping test with a duration of less than 24 hours</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVku"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVbt">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Brunnentest</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Pumpversuch zur Gewinnung der Leistungscharakteristik für den fertigen Brunnen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Pumping test in which the rates of drawdown are observed for several levels of constant, generally increasing, pump discharge rates. Step drawdown tests are often used to determine well efficiency.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVbt"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVgl">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Grundwasserleitertest</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Pumpversuch zur Ermittlung der hydraulischen Eigenschaften des Grundwasserleiters und der hydraulisch wirksamen Randbedingungen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Pumping test with constant flow rate to determine aquifer properties like transmissivity, porosity or aquifer boundaries.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVgl"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVko">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>kombinierter Brunnen-/Grundwasserleitertest</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Pumpversuch zur Gewinnung der Leistungscharakteristik für den fertigen Brunnen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Pumping test with phases of variable (well test) and constant flow rate (aquifer test) to determine the well characteristics and the properties of the aquifer. Both phases must be separated by a recovery phase.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVko"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVlz">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Langzeitpumpversuch</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Mehrere Wochen andauernder Grundwasserleitertest, z. B. zur Modellierung des Grundwasserleiters, zur Ermittlung der Dauerergiebigkeit und bei ökologischen Betrachtungen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Aquifer test with a duration of at least 31 days to evaluate longterm yield or ecologic effects of pumping.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVlz"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVzy">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>zyklischer Pumpversuch, Betriebsphase</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Pumpversuch mit auswertbarem Intervallbetrieb von Entnahmeraten und Ruhephasen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>pumping test with intervals of pumping and recovery phases</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/PVzy"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/AV">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Auslaufversuch</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Hydraulischer Versuch bei dem der natürlich vorhandene artesische Überdruck des Grundwassers und die Schüttung bei freiem Auslauf ausgewertet werden.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Discharge measurement of the artesian outflow at a spring or flowing well to evaluate geohydraulic properties.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/AV"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LV">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Lokale hydraulische Versuche</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Kontrollierte hydraulische Versuche die insbesonder den Nahfeldbereich einer Grundwassermessstelle betreffen.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Hydraulic tests for the investigation of the immediate surroundings of a well.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LV"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVsb">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Slug &amp; Bail-Test</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Schlagartige Veränderung des Grundwasserspiegels (Absenktest, Auffülltest) und Auswertung der Wiedereinstellung des Druckpotenzials.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>pulse test, sudden addition or removal of water  from a bore well and evaluation of water-table recovery to detemine near-well aquifer characteristics</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVsb"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVwd">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>WD-Test</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Wasserdruckversuch in einem mit Packern abgedichteten Testintervall. Der Versuch wird  z.T. auch als Packertest bezeichnet.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Water pressure test, WD test, Lugeon test, in which water is injected into a borehole section sealed with 1 or 2 packers. The test is therefore sometimes also referred to as a packer test. Its main field of application is the measurement of water permeability (e.g. for dam construction). The evaluation is carried out by means of curves of absorbed water quantity and injection pressure recorded during the test. Depending on how the test is carried out, a distinction is made between single and double packer tests as well as single and multi-stage tests.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVwd"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVds">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Drill-Stem-Test</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Aufbau eines Unterdrucks im Testintervall; Auswertung der Druckänderungen bei geschlossenem Abschnitt (Schließphase) und bei geöffnetem Abschnitt (Fließphase).</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>A drill stem test (DST) is a procedure for isolating and testing the pressure, permeability and productive capacity of a geological formation during the drilling of a well.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LVds"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LViv">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Injektionsversuch</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Erzeugung eines Überdrucks durch die Injektion von Wasser mit konstanter Injektionsrate und Auswertung der Wasserstandsänderung.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>Temporary injection of water into wells or groundwater measuring points to determine geohydraulic parameters of a rock body.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/LViv"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/EV">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Einschwingverfahren</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Mit dem Einschwingverfahren wird das Grundwasser in Schwingung gebracht und anschließend die Abnahme der Amplituden gemessen, anhand derer die Transmissivität bestimmt werden kann.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>The water level is set into oscillation and the damping of the amplitudes is measured, from which transmissivity can be inferred.</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/EV"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/so">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>Sonstige</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>Sonstige Verfahren zur Bestimmung geohydraulischer Kenngrößen eines Gesteinskörpers.</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>other methods for the determination of geohydraulic parameters of a rock body</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/so"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
   <containedItem xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/kA">
      <RE_RegisterItem>
         <itemIdentifier gco:nilReason="inapplicable"/>
         <name>
            <gco:CharacterString>keine Angabe</gco:CharacterString>
         </name>
         <status>
            <RE_ItemStatus>valid</RE_ItemStatus>
         </status>
         <definition>
            <gco:CharacterString>keine Angaben zum benutzten Verfahren</gco:CharacterString>
         </definition>
         <description>
            <gco:CharacterString>used method not specified</gco:CharacterString>
         </description>
         <additionInformation xlink:href="https://registry.gdi-de.org/codelist/de.sgd.hy/HYSL9/kA"/>
         <itemClass>
            <RE_ItemClass>
               <name>
                  <gco:CharacterString>CodeListValue_de.sgd.hy</gco:CharacterString>
               </name>
               <technicalStandard gco:nilReason="inapplicable"/>
               <alternativeNames gco:nilReason="inapplicable"/>
               <describedItem gco:nilReason="inapplicable"/>
            </RE_ItemClass>
         </itemClass>
      </RE_RegisterItem>
   </containedItem>
</RE_Register>